How to obtain the correct system time from the UC2000 VoIP gateway 2020-11-05
Technical Guides
How to get the correct system time on the UC2000
-
1. Overview
- When the CDR or SMS list shows an incorrect time, it can affect the use of the UC2000 VoIP GSM Gateway, including billing. This article explains how to correct the system time. The UC2000 obtains time in two ways: the device’s internal clock and the NTP server. If you choose to use the UC2000’s internal clock, the time will be reset after the UC2000 GSM VoIP gateway is restarted.
2. Check the UC2000 system time setting- If the UC2000 is connected to SIMCloud, the system time depends on the SIMCloud platform settings.
- If the UC2000 is not connected to SIMCloud, you must check the network and NTP settings.

3. Device Network- Try pinging the NTP server address on the UC2000 web page; if the address is reachable, it means the network is functional. If the address cannot be reached, check the network configuration. Ensure the UC2000 is properly connected to the network and that the DNS setting is correct. Then save the configurations and restart the device for the changes to take effect.


- If the UC2000 fails to connect to the network, you can set the local time via telnet.
3.1 Change system time via Telnet- First, connect to the device’s telnet using Putty. The device’s default telnet port is 23.

- Next, we can use the command to change the system time.
- Welcome to the command shell!
Username:admin
Password:*****
ROS>en
ROS#^config
ROS(config)#clock ?
set Set time and date,07/25/2003 13:25:43
ROS(config)#clock set 05/05/2019 18:18:18
ROS(config)#ex
ROS#sh clock
5/5/2019 18:18:25
ROS#
- Note:After restarting the UC2000, the system time will be reset. The command above can also be applied to all IAD devices.

4. NTP Parameter- If ping works but the system time is still incorrect, we need to check NTP settings. Please select the correct time zone, then set the appropriate NTP server address. If you do not have a recommended MTP server address, keep the default value. After completing the settings, save and restart the UC2000 for the changes to take effect.
- Note The UC2000 does not support daylight saving time, so we cannot set a GMT+2:30 time zone.